Compression refrigeration
Refrigerants are used in buildings:
- For heating, ventilation and air conditioning (HVAC) systems.
- To provide cooling for refrigeration.
- To provide cooling for industrial processes.
They provide cooling in a process that is essentially the same as that used in domestic fridges, based on either compression or absorption. Compression refrigeration is more common than absorption refrigeration.
In absorption refrigeration systems, a refrigerant that boils at low temperature and pressure is absorbed in a solution which is then heated in a ‘generator’ so that the refrigerant evaporates again, but this time at a higher pressure and temperature. The gas is then condensed, releasing its latent heat which is rejected. The process then repeats. See absorption refrigeration for more information.
In compression refrigeration, a circulating liquid refrigerant (such as a hydrofluorocarbon HFC) with a low boiling point absorbs heat from the body that is being cooled and boils in an evaporator to form a gas. The resulting gas is then compressed, which increases its temperature further. The gas is then condensed, releasing its latent heat which is rejected. The process then repeats.
The four primary components of a compression refrigeration system are:
- The compressor.
- The condenser.
- The metering device (which maintains the refrigerant in its condensed state and feeds it to the evaporator).
- The evaporator.
Typically in heating, ventilation and air conditioning systems, compression refrigeration takes place in chiller units which supply chilled water to the building that is in turn used to cool ventilation air in air handling units. Heat recovery can be used to allow the rejected heat from chiller units to be re-used for space heating or to provide hot water.
[edit] Related articles on Designing Buildings Wiki
- Absorption refrigeration.
- Air conditioning.
- Air conditioning inspection.
- Air handling unit.
- BREEAM Impact of refrigerants.
- BSRIA Compressor Study September 2020 - The Americas and China
- Chiller unit.
- Chilled water.
- Cooling systems for buildings.
- EMEA compressor market 2020 - 2023.
- Evaporative cooling.
- Heat pumps
- HVAC.
- Phase change.
- R22 phase out.
- Refrigerant.
- Refrigerant selection.
Featured articles
Check out some of the best features and news from Designing Buildings as well as key stories from around the web.
Your views needed - a strategy for the professions, trades and occupations.
Confronting competency, codes, capacity and costs.
The hidden risk in modern construction supply chains.
Construction Management, 10 June
24 months to 14: CITB launches accelerated apprenticeships.
Bridging the gap between clients and contractors
Concerns remain around contractor quality, capability, and delivery.
Construction Management, 10 June.
Heat pumps beat boilers in new home tests.
Building Safety Act implementation in Wales
CIAT to host industry panel on 26 June.
New and updated CLC building safety guidance.
New UK National Buildings Database.
Building Safety Wiki Interviews
Chief executive of the British Woodworking Federation.
Planning condition discharge in England and Wales
A brief explanation from a building compliance expert, with further links.